Files
orin-nano-env-setup/docs/impl/plans/POWER.md
T
2026-10-14 08:32:17 +09:00

3.3 KiB
Raw Blame History

type, status, updated
type status updated
plan active 2026-10-14

Car Power: Ride Through Cranking, Shut Down at Ignition Off

Power chain

cigarette socket (ignition-switched, 65 W class, crank-sensitive)
  → USB-C PD charger → 15 V PD trigger (15 V / 3 A) → DC jack
  → Waveshare UPS Power Module (C), 3S 21700, 15–19 V in, pass-through
  → Orin Nano carrier

Socket power is ignition-switched, so UPS input loss = ignition off or cranking. The UPS rides through cranking (bench: ≥ 20 s holdover across a supply swap). See BOM.

Detection

INA219 on I²C bus 7, 0x41, monitor-only (the UPS has no control lines). Battery current from the shunt-voltage register (0x01, 10 µV/LSB): about 0 or positive (charging) with input present, clearly negative (discharging) when input is lost. Battery voltage (0x02) is the backstop. To confirm on the bench: the sign convention and the discharge magnitude at the Orin's real load (pull the UPS input and read).

Policy (to build)

A small host service polling the INA219 about every 1 s:

State Condition Action
on input current ≥ about 0 nothing
on battery discharging, < grace publish system/power "on battery"; a short episode that recovers is a crank: stamp it into the recording
ignition off discharging continuously for grace (start at 60 s; tune after the car crank test) publish "shutting down" → stop capture (close the session cleanly) → optional parked-at-home step → systemctl poweroff
battery low built 2026-10-14 (svc-core orin-status --poweroff-below 11.0 --poweroff-after 30): below 11.0 V while discharging, 30 readings (1/s) in a row; a missing reading restarts the count state stopping on yukart/system/orin-status, then systemctl poweroff through svc-gw's polkit grant (no sudo)

Optional parked-at-home step: if home WiFi/LAN is reachable at ignition off, stay up long enough to copy recordings off over the LAN (same LAN-only rule as map sync, project-yukart decision 10), within a hard time cap, then shut down.

The battery-low row came first: on 2026-10-14 the pack ran flat overnight with the Orin up and nothing to stop it, and the boot's journal ends mid-stream at 06:29:22 (ext4 replayed its journal on the next boot; nothing lost). 11.0 V while discharging at the Orin's ~0.45 A is about 10 % charge, a margin for a clean shutdown; 30 s rides out a crank or a load spike. The ignition-off rows are still to build.

Open: getting the Orin back on at ignition on

After poweroff the UPS keeps supplying the board from its battery:

  1. Standby drain: the halted Orin still draws some power, so the pack drains while parked, until the UPS's over-discharge protection cuts out.
  2. No auto-start: the dev kit powers on when power appears. If the UPS output never dropped, ignition on doesn't boot the Orin.

Candidate fixes (hardware, to evaluate):

  • Cut the UPS output after shutdown (a latching relay or a timer on the output), so the next ignition-on is a real power-up.
  • Pulse the carrier's power-button header from a small circuit when socket power returns.
  • Suspend (SC7) instead of poweroff, with wake on a GPIO tied to socket power. Untested on this board, and still drains.

Until this is solved, ignition-off shutdown leaves the car unit off until someone power-cycles it.