@@ -149,9 +149,9 @@ re-dialling is the client's job. Noticing the loss and redelivering is the Orin'
Measured on the USB path (tablet ↔ PD hub ↔ Orin, 2026-10-09): cutting PD power Measured on the USB path (tablet ↔ PD hub ↔ Orin, 2026-10-09): cutting PD power
resets the hub's data port, and the link is back within ~3.5 s with no resets the hub's data port, and the link is back within ~3.5 s with no
intervention. Longer outages measured early on were the tablet sleeping on intervention. In the car that happens at every ignition change, cranking
battery, not the link. In the car this happens at every ignition included. Longer outages measured early on were the tablet sleeping on battery,
change. Design for it as normal operation. Requirements, not yet implemented: not the link. Design for drops as normal operation. Requirements, not yet implemented:
- **Failure detection on the Orin.** An app-level heartbeat with a timeout of a - **Failure detection on the Orin.** An app-level heartbeat with a timeout of a
few seconds, not TCP alone. A connection on a link that went down can stay few seconds, not TCP alone. A connection on a link that went down can stay