UPS: ups_pct_source and ups_charge_ah (counted charge); host.ndjson in capture sessions
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01DDwfd6Ki8UfG4hK6W5YpJz
This commit is contained in:
+17
-1
@@ -760,12 +760,28 @@
|
||||
"unit": "percent",
|
||||
"type": "number",
|
||||
"source": "host",
|
||||
"description": "UPS charge estimate from cell voltage, corrected for load. An estimate, steadiest at rest",
|
||||
"description": "UPS charge: counted from the current since the charger last stopped at full when ups_pct_source is 'counted'; otherwise the estimate from cell voltage, corrected for load, steadiest at rest",
|
||||
"range": [
|
||||
0,
|
||||
100
|
||||
]
|
||||
},
|
||||
"ups_pct_source": {
|
||||
"unit": "",
|
||||
"type": "string",
|
||||
"source": "host",
|
||||
"description": "Where ups_battery_pct comes from: 'counted' (current integrated since the last full charge, against the configured capacity) or 'voltage' (no full charge seen since the count was lost: pack out, Orin off a while, capacity changed)"
|
||||
},
|
||||
"ups_charge_ah": {
|
||||
"unit": "Ah",
|
||||
"type": "number",
|
||||
"source": "host",
|
||||
"description": "UPS charge counted since the last full charge; absent until there has been one",
|
||||
"range": [
|
||||
0,
|
||||
20
|
||||
]
|
||||
},
|
||||
"ups_state": {
|
||||
"unit": "",
|
||||
"type": "string",
|
||||
|
||||
Reference in New Issue